What are Ice Dams?
Ice damming occurs on roofs when snow on your roof melts and then refreezes near your gutters, often causing damage to your shingles.  Ice dams can occur on almost any residential roof in the Cincinnati and Northern Kentucky area.  The most common causes are inadequate insulation in the home and poor roof ventilation.  Ice dams most often occur in ranch style houses or houses with low roof slopes and large overhangs.

Ice dams occur when snow is present on the roof and the outside temperature is below freezing. Homes with poor insulation allow heat to escape from the living quarters into the attic. If the roof system is not properly ventilated, the heat will build up in the attic and warm the roof deck, melting the snow above. When the melted snow reaches cooler roof areas, usually the gutters or areas near the overhang (eaves) it will refreeze. This freeze-thaw process can damage shingled roofs since the ice can travel “upslope” and get underneath the shingles.

Prevention and Protection
Installing new shingles will not prevent ice dams.  Prevention only occurs when the entire roofing system is addressed, including attic insulation and roof ventilation.  Ideally, the temperature in the attic space should be close to the same temperature as the outside air.

  • Attic Insulation – adding insulation to your attic will minimize the heat that escapes from the living space into the attic.  Additionally, electric outlets, plumbing vents, furnace stacks, and bathroom vents can allow heat to escape into the attic.
  • Roof Ventilation – inevitably, heat will get into your attic during winter months.  Proper roof ventilation allows that heat to escape and prevents your roof deck from warming.  The freeze-thaw process that results in ice damming is unlikely to occur on a roof that is properly ventilated.
  • Underlayments, such as Grace Roofing’s Ice & Water Shield and  Owens Corning’s WeatherLock ice and water guard, protect the roof deck from ice dams by creating a water-tight barrier between the shingles and the roof deck, but do not prevent ice damming from occurring.

Air Vent, the industry leader in residential attic ventilation, introduces a NEW shingle-over, edge-of-roof installed intake vent – The Edge Vent. It not only provides continuous intake airflow at the roof’s edge but it significantly simplifies intake vent installation by keeping the roofing contractor on the roof.

And The Edge Vent puts the roofing contractor in complete control of the entire attic ventilation system. He no longer has to depend on the framer or the siding installer for intake vents.

More Info…

When your name is on the line, you need a product that is well known and trusted by customers. You also need a product that provides quality that is tested and proven. Our AttiCat Blown-In PINK Fiberglas™ Insulation products won’t settle or deteriorate with age, so there’s no danger of losing R-value over time.